PTS 死绳传感器
PTS-001 'Pit Bull' - Hook Load / Dead Line Sensor |
Part Number: PTS - 001
4...20 mA 2 wire current loop output Zone 0 Ex ia IIC Certified For up to 2.5" Cables Mechanics rated up to 200,000 lbs MS6 Connector Standard
IECEx
Certified to ATEX, IECEx and CSA
Field trials successful on three drilling rigs in Germany and Brazil!
Photo shows unit attached to 1" cable. Different inserts, magnetically attached to torque pin are used for different cable diameters.
A 3/4" Hex ratchet is provided and locked into place, though if it does go missing, any 3/4" Hex wrench will do the job. |
Technical Data | Connection Options | ||
Operating temp: | - 40 ...+ 60 degrees C | MS6, MS7, MS10 (available with junction box as well) | |
- 40 ...+ 140 degrees F | + Loop | Pin A | |
Load Cell Certification: | ATEX, CSA and IECEx | - Loop | Pin D |
Weight: | 22 lbs (10 kg) | ||
Protection: | IP 66 / X7 M | Installation | |
Material Load Cell: | Stainless Steel | Installed on the deadline side | |
Material Chassis: | Aluminum | Output is linearly proportional to tension on deadline | |
Material Clamp: | Stainless Steel | For 0.75” to 2.5” cable diameters | |
Advantages | Output Limits (always linear) | ||
-Easy MS6, MS7 or MS10 connection | At min weight, the output is 4mA (point set by user) | ||
-Easy to use clamp on design | At max weight, the output is 20mA (point set be user) | ||
-Fully interchangeable with existing units | |||
-Field replaceable load cell, in the event of a | |||
failure, only the actual load cell is replaced | |||
Certification | |||
IP 66 and Ex ia IIC | |||
From Load Cell | |||
Best suited to work with the following MTL | |||
isolator: MTL5541 | |||
Dimensions: